Part Number Hot Search : 
04820 1N5246 BCP55TA TP200 JYGC0118 00A12 LBN12018 LL101
Product Description
Full Text Search
 

To Download T4N320 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  0 7 0 2 _ t m a x l i b r o . i n d b 1 6 0702_tmaxlibro.indb 16 1 6 - 0 2 - 2 0 0 5 1 7 : 1 2 : 5 8 16-02-2005 17:12:58 free datasheet http:///
abb 1sdc007200c0201 7 /17 moulded case circuit-breakers tmax and isomax contents mccbs power distribution circuit-breakers technical data ............................................................................................................. 7 /20 ordering details reading information ............................................................................................... 7 /22 tmax t1 ................................................................................................................. 7 /23 tmax t2 ................................................................................................................. 7 /24 tmax t3 ................................................................................................................. 7 /28 tmax t4 ................................................................................................................. 7 /29 tmax t5 ................................................................................................................. 7 /35 isomax s6 .............................................................................................................. 7 /39 isomax s7 .............................................................................................................. 7 /49 circuit-breakers for applications up to 1000 v technical data ............................................................................................................. 7 /58 ordering details tmax t4 ................................................................................................................. 7 /59 tmax t5 ................................................................................................................. 7 /60 isomax s6, s6x, s7 ............................................................................................... 7 /61 switch disconnectors technical data ............................................................................................................. 7 /63 ordering details ........................................................................................................... 7 /64 fixed parts, conversion kit and breaking units ........................................................... 7 /67 accessories - tmax ........................................................................................................ 7 /70 accessories - isomax ..................................................................................................... 7 /80 dimensional details - tmax fixed circuit-breakers .................................................................................................. 7 /87 plug-in circuit-breakers ............................................................................................... 7 /101 withdrawable circuit-breakers .................................................................................... 7 /113 circuit-breakers with rc221/rc222 residual current release .................................... 7 /118 accessories ................................................................................................................ 7 /124 distance to be respected ............................................................................................ 7 /136 dimensional details - isomax fixed circuit-breakers .................................................................................................. 7 /137 withdrawable circuit-breakers .................................................................................... 7 /143 accessories ................................................................................................................ 7 /147 distance to be respected ............................................................................................ 7 /155 0 7 0 2 _ t m a x l i b r o . i n d b 1 7 0702_tmaxlibro.indb 17 1 6 - 0 2 - 2 0 0 5 1 7 : 1 3 : 1 7 16-02-2005 17:13:17 free datasheet http:///
1sdc007200c0201 7 /18 abb tmax and isomax moulded case circuit-breakers the moulded-case circuit-breakers, proposed by abb, derive from two families of apparatus: the well-known and consolidated isomax s series and the recent but already much awarded tmax series (top selection at intel design 2003 for their technological content and respect of the environment). in particular, tmax are characterised by an extremely high level of performances with limited overall dimensions, installation simplicity and an increasingly greater guarantee of safety for the operator thanks to their reinforced insulation. tmax circuit-breakers, thanks to their performances, completeness of protection releases and accessories, can be used for all distribution and sub-distribution application for both ac and dc electrical plants. the abb molded case circuit-breackers are proposed into seven sizes: t1, t2, t3, t4, t5, s6 and s7. the rated ultimate breaking capacity under short-circuit, icu, at 380/415 v ac is available starting from 16 ka up to 200 ka. to ful l the various application requirements, they are available in the following ranges: ?circuit-breakers for ac and dc power distribution ?circuit-breakers for motor protection ?circuit-breakers for applications up to 1000 v ac and dc ?switch-disconnectors. for each size, circuit-breakers are available in the three and four-pole versions. they are also equipped with a complete range of protection releases: thermomagnetic, magnetic only adjustable and electronic releases of the latest generation. t1, t2, t3, t4 and t5 and s6 circuit-breakers tted with tmd and tma thermomagnetic releases can also be used in direct current plants, with a eld of application from 1a to 800 a and a minimum operating voltage of 24 v dc. 0 7 0 2 _ t m a x l i b r o . i n d b 1 8 0702_tmaxlibro.indb 18 1 6 - 0 2 - 2 0 0 5 1 7 : 1 3 : 1 8 16-02-2005 17:13:18 free datasheet http:///
1sdc007200c0201 7 /19 abb mccbs general characteristics the abb family of moulded case circuit-breakers - tmax and isomax - is divided into different, perfectly integrated, ranges (tmax t1b 1p, t1, t2, t3, t4, t5 and isomax s6 and s7), able to cover a range of service currents from 1 to 1600 a. the power distribution circuit-breakers are available in the xed, plug-in or withdrawable, three-pole and four-pole versions. the tmax t1 circuit-breaker is also available in the single pole tmax t1b 1p version, with breaking capacities of 25 ka at 220/230 v ac. interchangeability of the releases the tmax t4 and t5 circuit-breakers can be tted either with thermomagnetic, magnetic only or electronic releases, which are all interchangeable with each other. in fact, thanks to the simplicity of their installation, the type of release can be replaced rapidly even by the end user, according to their requirements and needs: in this case, correct assembly remains the responsibility of the user himself. all this means increasing the exibility of use of the circuit-breakers, with considerable savings thanks to the better rationalization of stock management. conformity with standards the moulded-case circuit-breakers and their accessories conform to the iec 60947-2 international standards and comply with the ec ?ow voltage directives (lvd) no. 73/ 23 eec?and ?lectromagnetic compatibility directives (emc) no. 89/336 eec? abbs quality system conforms to the iso 9001 international standard and to the equivalent european en iso 9001 and italian uni en iso 9001 standards. the certifying body is the italian shipping register (rina - quacer): abb has reached its third quali cation con rmation. the abb test room is accredited by sinal. the apparatus conforms to the prescriptions of the on-board installations and approvals by the major shipping registers are in progress. tmax and isomax power distribution circuit-breakers 0 7 0 2 _ t m a x l i b r o . i n d b 1 9 0702_tmaxlibro.indb 19 1 6 - 0 2 - 2 0 0 5 1 7 : 1 3 : 1 9 16-02-2005 17:13:19 free datasheet http:///
1sdc007200c0201 7 /20 abb tmax and isomax power distribution circuit-breakers technical data tmax t1 1p tmax t1 tmax t2 rated uninterrupted current, iu (a) [iu] 160 160 160 poles [nr] 1 3-4 3-4 rated service voltage, ue (ac) 50-60 hz [v] 240 690 690 (dc) [v] 125 500 500 rated impulse withstand voltage, uimp [kv] 8 8 8 rated insulation voltage, ui [v] 500 800 800 test voltage at industrial frequency for 1 min. [v] 3000 3000 3000 rated ultimate short-circuit breaking capacity, icu b bcn nshl (ac) 50-60 hz 220/230 v [ka] 25 (1) 25 40 50 65 85 100 120 (ac) 50-60 hz 380/415 v [ka] 16 25 36 36 50 70 85 (ac) 50-60 hz 440 v [ka] 10 15 22 30 45 55 75 (ac) 50-60 hz 500 v [ka] 8 10 15 25 30 36 50 (ac) 50-60 hz 690 v [ka] 3 4 6 6 7 8 10 (dc) 250 v - 2 poles in series [ka] 25 (at 125 v) 16 25 36 36 50 70 85 (dc) 250 v - 3 poles in series [ka] 20 30 40 40 55 85 100 (dc) 500 v - 2 poles in series [ka] (dc) 500 v - 3 poles in series [ka] 16 25 36 36 50 70 85 (dc) 750 v - 3 poles in series [ka] rated short-circuit service breaking capacity , ics (at 415 v) [%icu] 75% 100% 100% 75% (3) 100% 100% 100% 75% (4) rated short-circuit making capacity, icm (415 v) [ka] 52.5 (at 220/230 v) 32 52.5 75.6 75.6 105 154 187 opening time (415 v) [ms] 7 7 6 5 3333 rated short-time withstand current for 1 s, icw [ka] utilisation category (iec 60947-2, en 60947-2) a a a isolation behaviour (iec 60947-2, en 60947-2) reference standard iec 60947-2, en 60947-2 releases: thermomagnetic t fixed, m fixed (10xin) tmf t adjustable, m fixed (3xin) tmg t adjustable, m fixed (10xin) tmd t adjustable, m adjustable (5...10xin) tma t adjustable, m adjustable (2,5...5xin) tmg magnetic only m adjustable (6...12xin) ma (mf up to in 12.5 a) electronic pr221ds (i-ls/i) pr222ds/p (lsi-lsig) pr223ds/p pr223ef pr211/p (i-li) pr212/p (lsi-lsig) pr222 mp pr212/mp interchangeability (for t4 and t5 only) versions f f f-p terminals fixed (f) fc cu fc cu - ef - fc cual -hr f - fc cu - fc cual - ef - es - r plug-in (p) f - fc cu - fc cual - ef - es - r withdrawable (w) fixing on din rail din en 50022 din en 50022 mechanical life [no. operations/hourly operations] 25000/240 25000/240 25000/240 electrical life (at 415 v) [no. operations/hourly operations] 8000/120 8000/120 8000/120 basic dimensions, fixed 3/4 poles w [mm] 25.4 (1 pole) 76/102 90/120 d [mm] 70 70 70 h[mm] 130 130 130 weights fixed 3/4 poles [kg] 0.4 (1 pole) 0.9/1.2 1.1/1.5 plug-in 3/4 poles [kg] 1.5/1.9 withdrawable 3/4 poles [kg] (3) 25 ka (4) 70 ka (5) 27 ka (6) for the s5 circuit-breaker, the plug-in version is only available for the version with 400 a rated current (1) r16 and r20 icu = 16 ka @ 220/230 v (2) all the versions with icu=35 ka are certified at 36 ka 0 7 0 2 _ t m a x 1 . i n d d 2 0 0702_tmax1.indd 20 4 - 0 3 - 2 0 0 5 1 2 : 1 6 : 1 4 4-03-2005 12:16:14 free datasheet http:///
1sdc007200c0201 7 /21 abb mccbs tmax t3 tmax t4 tmax t5 isomax s6 isomax s7 250 250/320 400/630 630 - 800 1250 - 1600 3-4 3-4 3-4 3-4 3-4 690 690 690 690 690 500 750 750 750 ? 88 8 88 800 1000 1000 800 800 3000 3500 3500 3000 3000 ns nshlv nshlv nshl s h l 50 85 70 85 100 200 300 70 85 100 200 300 65 85 100 200 85 100 200 36 50 36 50 70 120 200 36 50 70 120 200 35 (2) 50 65 100 50 65 100 25 40 30 40 65 100 180 30 40 65 100 180 30 45 50 80 40 55 80 20 30 25 30 50 85 150 25 30 50 85 150 25 35 40 65 35 45 70 5 8 20 25 40 70 80 20 25 40 70 80 20 22 25 30 20 25 35 36 50 36 50 70 100 150 36 50 70 100 150 35 50 65 100 ? ? ? 40 55 25 36 50 70 100 25 36 50 70 100 20 35 50 65 ? ? ? 36 50 ???? ? ? ? 16 25 36 50 70 16 25 36 50 70 16 20 35 50 ? ? ? 75% 50% (5) 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 75% 100% 75% 50% 75.6 105 75.6 105 154 264 440 75.6 105 154 264 440 74 105 143 220 105 143 220 76 55555 66666 10987 222222 7.6 (630 a) - 10 (800 a) 15 (1250 a) - 20 (1600 a) a a b (400 a) (6) - a (630 a) b b (up to 50 a) (up to 250 a) (up to 500 a) (up to 500 a) f-p f - p- w f - p -w f - w f - w f - fc cu - fc cual - ef - es - r f-fc-cu-fc cual- ef-es-r-mc f-fc cu-fc cual-ef-es-r f - ef - es - fc (cual) - rc - r f - ef - es - fc cual (1250 a) - hr - vr f - fc cu - fc cual - ef - es - r ef-es-hr-vr-f c cu-fc cual ef-es-hr-vr- fc cu-fc cual ?? ef-es-hr-vr-fc cu-fc cual ef-es-hr-vr-fc cu-fc cual ef - hr - vr ef - hr - vr din en 50022 ?? 25000/240 20000/240 20000/120 20000/120 10000/120 8000/120 8000 (250 a) - 6000 (320 a)/120 7000 (400 a) - 5000 (630 a)/60 7000 (630 a) - 5000 (800 a)/60 7000 (1250 a) - 5000 (1600 a)/20 105/140 105/140 140/184 210/280 210/280 70 103.5 103.5 103.5 138.5 150 205 205 268 406 2.1/3 2.35/3.05 3.25/4.15 9.5/12 17/22 2.7/3.7 3.6/4.65 5.15/6.65 ? ? 3.85/4.9 5.4/6.9 12.1/15.1 21.8/29.2 key to terminals: f = front ef = extended front es = extended spreaded front fc = front for copper cables fc cual = fr ont for copper or aluminium cables r = rear rc = rear for copper or aluminium cables hr = rear horizontal flat bar vr = rear vertical flat bar 0 7 0 2 _ t m a x 1 . i n d d 2 1 0702_tmax1.indd 21 4 - 0 3 - 2 0 0 5 1 2 : 1 6 : 2 8 4-03-2005 12:16:28 free datasheet http:///
1sdc007200c0201 7 /22 abb electronic releases tmax pr221ds = electronic protection release; functions i, ls/i isomax pr211/p = electronic protection release; functions i, li pr222ds = electronic protection release; functions lsi, lsig; available also in the /pd version with dialogue functions (modbus) pr212/p = electronic protection release; functions lsi, lsig pr222mp = electronic protection release for motor protection; functions lriu pr212/mp = electronic protection release for motor protection; functions lriu tmax and isomax power distribution circuit-breakers ordering details - reading information i 3 in iu icu n= 50% n= 100% abbreviations used to describe the apparatus type of connection terminals: f = front terminals ef = front extended terminals es = front extended spread terminals fc cu = front terminals for copper cables fc cual = front terminals for cu/al cables fc cual = front terminals for cu/al cables (housed ex ter nal ly) r = rear terminals (tmax) magnetic trip current [a] rated current of the protection release [a] rated un in ter rupt ed current of the circuit-breaker [a] rated ultimate short-circuit break ing capacity [a] protection of the neu tral at 50% or at 100% of that of the phases [a] tmf = thermomagnetic release with xed thermal and magnetic threshold tmd = thermomagnetic release with adjustable thermal and xed magnetic threshold tma = thermomagnetic release with adjustable thermal and magnetic threshold tmg = thermomagnetic release for generator protection mf = fixed magnetic only releases ma = adjustable magnetic only releases pr22_ = electronic releases (tmax) pr12_ = electronic releases (isomax) hr for rc221/222 = rear at horizontal terminals hr = rear at horizontal terminals vr = rear at vertical terminals mc = multi- cable terminals r = threaded rear terminals (isomax) rc = rear terminals for cables icw rated short-time withstand current type of currents: type of protection releases: 0 7 0 2 _ t m a x l i b r o . i n d b 2 2 0702_tmaxlibro.indb 22 1 6 - 0 2 - 2 0 0 5 1 7 : 1 3 : 2 7 16-02-2005 17:13:27 free datasheet http:///
1sdc007200c0201 7 /23 abb mccbs see ?abbreviation caption? page 7 /22 t1c 160 fixed (f), iu (40 c) = 160 a - icu (415 v) = 25 ka fc cu = front terminals for copper ca bles in i 3 1sda.....r1 3 poles 4 poles thermomagnetic release - tmd n= 50% n= 100% t1c 160 f fc cu (1x70mm 2 ) 25 500 050894 050905 t1c 160 f fc cu (1x70mm 2 ) 32 500 050895 050906 t1c 160 f fc cu (1x70mm 2 ) 40 500 050896 050907 t1c 160 f fc cu (1x70mm 2 ) 50 500 050897 050908 t1c 160 f fc cu (1x70mm 2 ) 63 630 050898 050909 t1c 160 f fc cu (1x70mm 2 ) 80 800 050899 050910 t1c 160 f fc cu (1x70mm 2 ) 100 1000 050900 050911 t1c 160 f fc cu (1x70mm 2 ) 125 1250 050901 050912 t1c 160 f fc cu (1x70mm 2 ) 160 1600 050902 050913 050937 t1n 160 fixed (f), iu (40 c) = 160 a - icu (415 v) = 36 ka fc cu = front terminals for copper ca bles in i 3 1sda.....r1 3 poles 4 poles thermomagnetic release - tmd n= 50% n= 100% t1n 160 f fc cu (1x70mm 2 ) 32 500 050917 050928 t1n 160 f fc cu (1x70mm 2 ) 40 500 050918 050929 t1n 160 f fc cu (1x70mm 2 ) 50 500 050919 050930 t1n 160 f fc cu (1x70mm 2 ) 63 630 050920 050931 t1n 160 f fc cu (1x70mm 2 ) 80 800 050921 050932 t1n 160 f fc cu (1x70mm 2 ) 100 1000 050922 050933 t1n 160 f fc cu (1x70mm 2 ) 125 1250 050923 050934 t1n 160 f fc cu (1x70mm 2 ) 160 1600 050924 050935 050938 1sdc210302f0004 1sdc210180f0004 t1b 160 fixed (f), iu (40 c) = 160 a - icu (415 v) = 16 ka fc cu = front terminals for copper ca bles in i 3 1sda.....r1 3 poles 4 poles thermomagnetic release - tmd n= 50% n= 100% t1b 160 f fc cu (1x70mm 2 ) 16 500 050870 050881 t1b 160 f fc cu (1x70mm 2 ) 20 500 050871 050882 t1b 160 f fc cu (1x70mm 2 ) 25 500 050872 050883 t1b 160 f fc cu (1x70mm 2 ) 32 500 050873 050884 t1b 160 f fc cu (1x70mm 2 ) 40 500 050874 050885 t1b 160 f fc cu (1x70mm 2 ) 50 500 050875 050886 t1b 160 f fc cu (1x70mm 2 ) 63 630 050876 050887 t1b 160 f fc cu (1x70mm 2 ) 80 800 050877 050888 t1b 160 f fc cu (1x70mm 2 ) 100 1000 050878 050889 t1b 160 f fc cu (1x70mm 2 ) 125 1250 050879 050890 t1b 160 f fc cu (1x70mm 2 ) 160 1600 050880 050891 050936 tmax and isomax power distribution circuit-breakers ordering details - t1 t1b 1p 160 fixed (f), iu (40 c) = 160 a - icu (230 v) = 25 ka fc cu = front terminals for copper ca bles in i 3 1sda.....r1 1 pole thermomagnetic release with ? xed thresholds - tmf t1b 1p 160 f fc cu (1x70mm 2 ) 16 500 052616 t1b 1p 160 f fc cu (1x70mm 2 ) 20 500 052617 t1b 1p 160 f fc cu (1x70mm 2 ) 25 500 052618 t1b 1p 160 f fc cu (1x70mm 2 ) 32 500 052619 t1b 1p 160 f fc cu (1x70mm 2 ) 40 500 052620 t1b 1p 160 f fc cu (1x70mm 2 ) 50 500 052621 t1b 1p 160 f fc cu (1x70mm 2 ) 63 630 052622 t1b 1p 160 f fc cu (1x70mm 2 ) 80 800 052623 t1b 1p 160 f fc cu (1x70mm 2 ) 100 1000 052624 t1b 1p 160 f fc cu (1x70mm 2 ) 125 1250 052625 t1b 1p 160 f fc cu (1x70mm 2 ) 160 1600 052626 0 7 0 2 _ t m a x 1 . i n d d 2 3 0702_tmax1.indd 23 4 - 0 3 - 2 0 0 5 1 2 : 1 7 : 3 7 4-03-2005 12:17:37 free datasheet http:///
1sdc007200c0201 7 /24 abb see ?abbreviation caption? page 7 /22 t2n 160 fixed (f), iu (40 c) = 160 a - icu (415 v) = 36 ka f = front terminals in 1sda.....r1 3 poles 4 poles electronic release n= 50% n= 100% t2n 160 f f pr221ds-ls 10 051123 051128 t2n 160 f f pr221ds-ls 25 051124 051129 t2n 160 f f pr221ds-ls 63 051125 051130 t2n 160 f f pr221ds-ls 100 051126 051131 t2n 160 f f pr221ds-ls 160 051127 051132 051613 t2n 160 f f pr221ds-i 10 051163 051169 t2n 160 f f pr221ds-i 25 051164 051170 t2n 160 f f pr221ds-i 63 051165 051171 t2n 160 f f pr221ds-i 100 051166 051172 t2n 160 f f pr221ds-i 160 051168 051173 051617 tmax and isomax power distribution circuit-breakers ordering details - t2 note: the trip coil of the t2 circuit-breaker with pr221ds electronic release is housed in the right slot. when or dered, the set of auxiliary contacts for electronic t2 (1sda?r1) is available, consisting of: 1 open/closed contact for signalling electronic release trip 1 open/closed contact for signalling release trip 1 open/closed contact for signalling state of the circuit-breaker f = front terminals in i 3 1sda.....r1 3 poles 4 poles thermomagnetic release - tmd n= 50% n= 100% t2n 160 f f 1.6 16 050940 050962 t2n 160 f f 2 20 050941 050963 t2n 160 f f 2.5 25 050942 050964 t2n 160 f f 3.2 32 050943 050965 t2n 160 f f 4 40 050944 050966 t2n 160 f f 5 50 050945 050967 t2n 160 f f 6.3 63 050946 050968 t2n 160 f f 8 80 050947 050969 t2n 160 f f 10 100 050948 050970 t2n 160 f f 12.5 125 050949 050971 t2n 160 f f 16 500 050950 050972 t2n 160 f f 20 500 050951 050973 t2n 160 f f 25 500 050952 050974 t2n 160 f f 32 500 050953 050975 t2n 160 f f 40 500 050954 050976 t2n 160 f f 50 500 050955 050977 t2n 160 f f 63 630 050956 050978 t2n 160 f f 80 800 050957 050979 t2n 160 f f 100 1000 050958 050980 t2n 160 f f 125 1250 050959 050981 051115 t2n 160 f f 160 1600 050960 050982 051116 1sdc210303f0004 0 7 0 2 _ t m a x 1 . i n d d 2 4 0702_tmax1.indd 24 4 - 0 3 - 2 0 0 5 1 2 : 1 7 : 4 6 4-03-2005 12:17:46 free datasheet http:///
1sdc007200c0201 7 /25 abb mccbs see ?abbreviation caption? page 7 /22 tmax and isomax power distribution circuit-breakers ordering details - t2 f = front terminals in i 3 1sda.....r1 3 poles 4 poles thermomagnetic release - tmd n= 50% n= 100% t2s 160 f f 1.6 16 050984 051006 t2s 160 f f 2 20 050985 051007 t2s 160 f f 2.5 25 050986 051008 t2s 160 f f 3.2 32 050987 051009 t2s 160 f f 4 40 050988 051010 t2s 160 f f 5 50 050989 051011 t2s 160 f f 6.3 63 050990 051012 t2s 160 f f 8 80 050991 051013 t2s 160 f f 10 100 050992 051014 t2s 160 f f 12.5 125 050993 051015 t2s 160 f f 16 500 050994 051016 t2s 160 f f 20 500 050995 051017 t2s 160 f f 25 500 050996 051018 t2s 160 f f 32 500 050997 051019 t2s 160 f f 40 500 050998 051020 t2s 160 f f 50 500 050999 051021 t2s 160 f f 63 630 051000 051022 t2s 160 f f 80 800 051001 051023 t2s 160 f f 100 1000 051002 051024 t2s 160 f f 125 1250 051003 051025 051117 t2s 160 f f 160 1600 051004 051026 051118 t2s 160 fixed (f), iu (40 c) = 160 a - icu (415 v) = 50 ka f = front terminals in 1sda.....r1 3 poles 4 poles electronic release n= 50% n= 100% t2s 160 f f pr221ds-ls 10 051133 051138 t2s 160 f f pr221ds-ls 25 051134 051139 t2s 160 f f pr221ds-ls 63 051135 051140 t2s 160 f f pr221ds-ls 100 051136 051141 t2s 160 f f pr221ds-ls 160 051137 051142 051614 t2s 160 f f pr221ds-i 10 051174 051179 t2s 160 f f pr221ds-i 25 051175 051180 t2s 160 f f pr221ds-i 63 051176 051181 t2s 160 f f pr221ds-i 100 051177 051182 t2s 160 f f pr221ds-i 160 051178 051183 051618 note: the trip coil of the t2 circuit-breaker with pr221ds electronic release is housed in the right slot. when or dered, the set of auxiliary contacts for electronic t2 (1sda?r1) is available, consisting of: 1 open/closed contact for signalling electronic release trip 1 open/closed contact for signalling release trip 1 open/closed contact for signalling state of the circuit-breaker 1sdc210303f0004 0 7 0 2 _ t m a x 1 . i n d d 2 5 0702_tmax1.indd 25 4 - 0 3 - 2 0 0 5 1 2 : 1 7 : 4 7 4-03-2005 12:17:47 free datasheet http:///
1sdc007200c0201 7 /26 abb see ?abbreviation caption? page 7 /22 f = front terminals in i 3 1sda.....r1 3 poles 4 poles thermomagnetic release - tmd n= 50% n= 100% t2h 160 f f 1.6 16 051028 051050 t2h 160 f f 2 20 051029 051051 t2h 160 f f 2.5 25 051030 051052 t2h 160 f f 3.2 32 051031 051053 t2h 160 f f 4 40 051032 051054 t2h 160 f f 5 50 051033 051055 t2h 160 f f 6.3 63 051034 051056 t2h 160 f f 8 80 051035 051057 t2h 160 f f 10 100 051036 051058 t2h 160 f f 12.5 125 051037 051059 t2h 160 f f 16 500 051038 051060 t2h 160 f f 20 500 051039 051061 t2h 160 f f 25 500 051040 051062 t2h 160 f f 32 500 051041 051063 t2h 160 f f 40 500 051042 051064 t2h 160 f f 50 500 051043 051065 t2h 160 f f 63 630 051044 051066 t2h 160 f f 80 800 051045 051067 t2h 160 f f 100 1000 051046 051068 t2h 160 f f 125 1250 051047 051069 051119 t2h 160 f f 160 1600 051048 051070 051120 tmax and isomax power distribution circuit-breakers ordering details - t2 t2h 160 fixed (f), iu (40 c) = 160 a - icu (415 v) = 70 ka f = front terminals in 1sda.....r1 3 poles 4 poles electronic release n= 50% n= 100% t2h 160 f f pr221ds-ls 10 051143 051148 t2h 160 f f pr221ds-ls 25 051144 051149 t2h 160 f f pr221ds-ls 63 051145 051150 t2h 160 f f pr221ds-ls 100 051146 051151 t2h 160 f f pr221ds-ls 160 051147 051152 051615 t2h 160 f f pr221ds-i 10 051184 051189 t2h 160 f f pr221ds-i 25 051185 051190 t2h 160 f f pr221ds-i 63 051186 051191 t2h 160 f f pr221ds-i 100 051187 051192 t2h 160 f f pr221ds-i 160 051188 051193 051619 note: the trip coil of the t2 circuit-breaker with pr221ds electronic release is housed in the right slot. when or dered, the set of auxiliary contacts for electronic t2 (1sda?r1) is available, consisting of: 1 open/closed contact for signalling electronic release trip 1 open/closed contact for signalling release trip 1 open/closed contact for signalling state of the circuit-breaker 1sdc210303f0004 0 7 0 2 _ t m a x 1 . i n d d 2 6 0702_tmax1.indd 26 4 - 0 3 - 2 0 0 5 1 2 : 1 7 : 4 8 4-03-2005 12:17:48 free datasheet http:///
1sdc007200c0201 7 /27 abb mccbs see ?abbreviation caption? page 7 /22 f = front terminals in i 3 1sda.....r1 3 poles 4 poles thermomagnetic release - tmd n= 50% n= 100% t2l 160 f f 1.6 16 051072 051094 t2l 160 f f 2 20 051073 051095 t2l 160 f f 2.5 25 051074 051096 t2l 160 f f 3.2 32 051075 051097 t2l 160 f f 4 40 051076 051098 t2l 160 f f 5 50 051077 051099 t2l 160 f f 6.3 63 051078 051100 t2l 160 f f 8 80 051079 051101 t2l 160 f f 10 100 051080 051102 t2l 160 f f 12.5 125 051081 051103 t2l 160 f f 16 500 051082 051104 t2l 160 f f 20 500 051083 051105 t2l 160 f f 25 500 051084 051106 t2l 160 f f 32 500 051085 051107 t2l 160 f f 40 500 051086 051108 t2l 160 f f 50 500 051087 051109 t2l 160 f f 63 630 051088 051110 t2l 160 f f 80 800 051089 051111 t2l 160 f f 100 1000 051090 051112 t2l 160 f f 125 1250 051091 051113 051121 t2l 160 f f 160 1600 051092 051114 051122 tmax and isomax power distribution circuit-breakers ordering details - t2 t2l 160 fixed (f), iu (40 c) = 160 a - icu (415 v) = 85 ka f = front terminals in 1sda.....r1 3 poles 4 poles electronic release n= 50% n= 100% t2l 160 f f pr221ds-ls 10 051153 051158 t2l 160 f f pr221ds-ls 25 051154 051159 t2l 160 f f pr221ds-ls 63 051155 051160 t2l 160 f f pr221ds-ls 100 051156 051161 t2l 160 f f pr221ds-ls 160 051157 051162 051162 t2l 160 f f pr221ds-i 10 051194 051199 t2l 160 f f pr221ds-i 25 051195 051200 t2l 160 f f pr221ds-i 63 051196 051201 t2l 160 f f pr221ds-i 100 051197 051202 t2l 160 f f pr221ds-i 160 051198 051203 051620 note: the trip coil of the t2 circuit-breaker with pr221ds electronic release is housed in the right slot. when or dered, the set of auxiliary contacts for electronic t2 (1sda?r1) is available, consisting of: 1 open/closed contact for signalling electronic release trip 1 open/closed contact for signalling release trip 1 open/closed contact for signalling state of the circuit-breaker 1sdc210303f0004 0 7 0 2 _ t m a x 1 . i n d d 2 7 0702_tmax1.indd 27 4 - 0 3 - 2 0 0 5 1 2 : 1 7 : 4 9 4-03-2005 12:17:49 free datasheet http:///
1sdc007200c0201 7 /28 abb see ?abbreviation caption? page 7 /22 t3n 250 fixed (f), iu (40 c) = 250 a - icu (415 v) = 36 ka f = front terminals in i 3 1sda.....r1 3 poles 4 poles thermomagnetic release - tmd n= 50% n= 100% t3n 250 f f 63 630 051241 051252 t3n 250 f f 80 800 051242 051253 t3n 250 f f 100 1000 051243 051254 t3n 250 f f 125 1250 051244 051255 051303 t3n 250 f f 160 1600 051245 051256 051304 t3n 250 f f 200 2000 051246 051257 051305 t3n 250 f f 250 2500 051247 051258 051306 thermomagnetic release for generator protection - tmg n= 100% t3n 250 f f 63 400 055105 055112 t3n 250 f f 80 400 055106 055113 t3n 250 f f 100 400 055107 055114 t3n 250 f f 125 400 055108 055115 t3n 250 f f 160 480 055109 055116 t3n 250 f f 200 600 055110 055117 t3n 250 f f 250 750 055111 055118 t3s 250 fixed (f), iu (40 c) = 250 a - icu (415 v) = 50 ka f = front terminals in i 3 1sda.....r1 3 poles 4 poles thermomagnetic release - tmd n= 50% n= 100% t3s 250 f f 63 630 051263 051274 t3s 250 f f 80 800 051264 051275 t3s 250 f f 100 1000 051265 051276 t3s 250 f f 125 1250 051266 051277 051307 t3s 250 f f 160 1600 051267 051278 051308 t3s 250 f f 200 2000 051268 051279 051309 t3s 250 f f 250 2500 051269 051280 051310 thermomagnetic release for generator protection - tmg n= 100% t3s 250 f f 63 400 055119 055126 t3s 250 f f 80 400 055120 055127 t3s 250 f f 100 400 055121 055128 t3s 250 f f 125 400 055122 055129 t3s 250 f f 160 480 055123 055130 t3s 250 f f 200 600 055124 055131 t3s 250 f f 250 750 055125 055132 tmax and isomax power distribution circuit-breakers ordering details - t3 1sdc210304f0004 0 7 0 2 _ t m a x 1 . i n d d 2 8 0702_tmax1.indd 28 4 - 0 3 - 2 0 0 5 1 2 : 1 7 : 5 0 4-03-2005 12:17:50 free datasheet http:///
1sdc007200c0201 7 /29 abb mccbs see ?abbreviation caption? page 7 /22 t4n 250 fixed (f), iu (40 c) = 250 a - icu (415 v) = 36 ka f = front terminals in 1sda.....r1 3 poles 4 poles electronic release t4n 250 f f pr221ds-ls/i 100 053997 054009 t4n 250 f f pr221ds-ls/i 160 053998 054010 t4n 250 f f pr221ds-ls/i 250 053999 054011 t4n 250 f f pr221ds-i 100 054000 054012 t4n 250 f f pr221ds-i 160 054001 054013 t4n 250 f f pr221ds-i 250 054002 054014 t4n 250 f f pr222ds/p-lsi 100 054003 054015 t4n 250 f f pr222ds/p-lsi 160 054004 054016 t4n 250 f f pr222ds/p-lsi 250 054005 054017 t4n 250 f f pr222ds/p-lsig 100 054006 054018 t4n 250 f f pr222ds/p-lsig 160 054007 054019 t4n 250 f f pr222ds/p-lsig 250 054008 054020 t4n 320 fixed (f), iu (40 c) = 320 a - icu (415 v) = 36 ka f = front terminals in 1sda.....r1 3 poles 4 poles electronic release t4n 320 f f pr221ds-ls/i 320 054117 054121 t4n 320 f f pr221ds-i 320 054118 054122 t4n 320 f f pr222ds/p-lsi 320 054119 054123 t4n 320 f f pr222ds/p-lsig 320 054120 054124 tmax and isomax power distribution circuit-breakers ordering details - t4 f = front terminals in i 3 1sda.....r1 3 poles 4 poles thermomagnetic release - tmd and tma n= 50% n= 100% t4n 250 f f 20 320 054171 054180 t4n 250 f f 32 320 054172 054181 t4n 250 f f 50 500 054173 054182 t4n 250 f f 80 400...800 054174 054183 t4n 250 f f 100 500...1000 054175 054184 t4n 250 f f 125 625...1250 054176 054185 054271 t4n 250 f f 160 800...1600 054177 054186 054272 t4n 250 f f 200 1000...2000 054178 054187 054273 t4n 250 f f 250 1250...2500 054179 054188 054274 1sdc210305f0004 0 7 0 2 _ t m a x 1 . i n d d 2 9 0702_tmax1.indd 29 4 - 0 3 - 2 0 0 5 1 2 : 1 7 : 5 1 4-03-2005 12:17:51 free datasheet http:///
1sdc007200c0201 7 /30 abb see ?abbreviation caption? page 7 /22 t4s 250 fixed (f), iu (40 c) = 250 a - icu (415 v) = 50 ka f = front terminals in 1sda.....r1 3 poles 4 poles electronic release t4s 250 f f pr221ds-ls/i 100 054021 054033 t4s 250 f f pr221ds-ls/i 160 054022 054034 t4s 250 f f pr221ds-ls/i 250 054023 054035 t4s 250 f f pr221ds-i 100 054024 054036 t4s 250 f f pr221ds-i 160 054025 054037 t4s 250 f f pr221ds-i 250 054026 054038 t4s 250 f f pr222ds/p-lsi 100 054027 054039 t4s 250 f f pr222ds/p-lsi 160 054028 054040 t4s 250 f f pr222ds/p-lsi 250 054029 054041 t4s 250 f f pr222ds/p-lsig 100 054030 054042 t4s 250 f f pr222ds/p-lsig 160 054031 054043 t4s 250 f f pr222ds/p-lsig 250 054032 054044 f = front terminals in i 3 1sda.....r1 3 poles 4 poles thermomagnetic release - tmd and tma n= 50% n= 100% t4s 250 f f 20 320 054189 054198 t4s 250 f f 32 320 054190 054199 t4s 250 f f 50 500 054191 054200 t4s 250 f f 80 400...800 054192 054201 t4s 250 f f 100 500...1000 054193 054202 t4s 250 f f 125 625...1250 054194 054203 054275 t4s 250 f f 160 800...1600 054195 054204 054276 t4s 250 f f 200 1000...2000 054196 054205 054277 t4s 250 f f 250 1250...2500 054197 054206 054278 t4s 320 fixed (f), iu (40 c) = 320 a - icu (415 v) = 50 ka f = front terminals in 1sda.....r1 3 poles 4 poles electronic release t4s 320 f f pr221ds-ls/i 320 054125 054129 t4s 320 f f pr221ds-i 320 054126 054130 t4s 320 f f pr222ds/p-lsi 320 054127 054131 t4s 320 f f pr222ds/p-lsig 320 054128 054132 tmax and isomax power distribution circuit-breakers ordering details - t4 1sdc210305f0004 0 7 0 2 _ t m a x 1 . i n d d 3 0 0702_tmax1.indd 30 4 - 0 3 - 2 0 0 5 1 2 : 1 7 : 5 2 4-03-2005 12:17:52 free datasheet http:///
1sdc007200c0201 7 /31 abb mccbs see ?abbreviation caption? page 7 /22 t4h 250 fixed (f), iu (40 c) = 250 a - icu (415 v) = 70 ka f = front terminals in 1sda.....r1 3 poles 4 poles electronic release t4h 250 f f pr221ds-ls/i 100 054045 054057 t4h 250 f f pr221ds-ls/i 160 054046 054058 t4h 250 f f pr221ds-ls/i 250 054047 054059 t4h 250 f f pr221ds-i 100 054048 054060 t4h 250 f f pr221ds-i 160 054049 054061 t4h 250 f f pr221ds-i 250 054050 054062 t4h 250 f f pr222ds/p-lsi 100 054051 054063 t4h 250 f f pr222ds/p-lsi 160 054052 054064 t4h 250 f f pr222ds/p-lsi 250 054053 054065 t4h 250 f f pr222ds/p-lsig 100 054054 054066 t4h 250 f f pr222ds/p-lsig 160 054055 054067 t4h 250 f f pr222ds/p-lsig 250 054056 054068 f = front terminals in i 3 1sda.....r1 3 poles 4 poles thermomagnetic release - tmd and tma n= 50% n= 100% t4h 250 f f 20 320 054207 054216 t4h 250 f f 32 320 054208 054217 t4h 250 f f 50 500 054209 054218 t4h 250 f f 80 400...800 054210 054219 t4h 250 f f 100 500...1000 054211 054220 t4h 250 f f 125 625...1250 054212 054221 054279 t4h 250 f f 160 800...1600 054213 054222 054280 t4h 250 f f 200 1000...2000 054214 054223 054281 t4h 250 f f 250 1250...2500 054215 054224 054282 t4h 320 fixed (f), iu (40 c) = 320 a - icu (415 v) = 70 ka f = front terminals in 1sda.....r1 3 poles 4 poles electronic release t4h 320 f f pr221ds-ls/i 320 054133 054137 t4h 320 f f pr221ds-i 320 054134 054138 t4h 320 f f pr222ds/p-lsi 320 054135 054139 t4h 320 f f pr222ds/p-lsig 320 054136 054140 tmax and isomax power distribution circuit-breakers ordering details - t4 1sdc210305f0004 0 7 0 2 _ t m a x 1 . i n d d 3 1 0702_tmax1.indd 31 4 - 0 3 - 2 0 0 5 1 2 : 1 7 : 5 3 4-03-2005 12:17:53 free datasheet http:///
1sdc007200c0201 7 /32 abb see ?abbreviation caption? page 7 /22 t4l 250 fixed (f), iu (40 c) = 250 a - icu (415 v) = 120 ka f = front terminals in 1sda.....r1 3 poles 4 poles electronic release t4l 250 f f pr221ds-ls/i 100 054069 054081 t4l 250 f f pr221ds-ls/i 160 054070 054082 t4l 250 f f pr221ds-ls/i 250 054071 054083 t4l 250 f f pr221ds-i 100 054072 054084 t4l 250 f f pr221ds-i 160 054073 054085 t4l 250 f f pr221ds-i 250 054074 054086 t4l 250 f f pr222ds/p-lsi 100 054075 054087 t4l 250 f f pr222ds/p-lsi 160 054076 054088 t4l 250 f f pr222ds/p-lsi 250 054077 054089 t4l 250 f f pr222ds/p-lsig 100 054078 054090 t4l 250 f f pr222ds/p-lsig 160 054079 054091 t4l 250 f f pr222ds/p-lsig 250 054080 054092 f = front terminals in i 3 1sda.....r1 3 poles 4 poles thermomagnetic release - tmd and tma n= 50% n= 100% t4l 250 f f 20 320 054225 054234 t4l 250 f f 32 320 054226 054235 t4l 250 f f 50 500 054227 054236 t4l 250 f f 80 400...800 054228 054237 t4l 250 f f 100 500...1000 054229 054238 t4l 250 f f 125 625...1250 054230 054239 054283 t4l 250 f f 160 800...1600 054231 054240 054284 t4l 250 f f 200 1000...2000 054232 054241 054285 t4l 250 f f 250 1250...2500 054233 054242 054286 t4l 320 fixed (f), iu (40 c) = 320 a - icu (415 v) = 120 ka f = front terminals in 1sda.....r1 3 poles 4 poles electronic release t4l 320 f f pr221ds-ls/i 320 054141 054145 t4l 320 f f pr221ds-i 320 054142 054146 t4l 320 f f pr222ds/p-lsi 320 054143 054147 t4l 320 f f pr222ds/p-lsig 320 054144 054148 tmax and isomax power distribution circuit-breakers ordering details - t4 1sdc210305f0004 0 7 0 2 _ t m a x 1 . i n d d 3 2 0702_tmax1.indd 32 4 - 0 3 - 2 0 0 5 1 2 : 1 7 : 5 3 4-03-2005 12:17:53 free datasheet http:///
1sdc007200c0201 7 /33 abb mccbs see ?abbreviation caption? page 7 /22 1sdc210305f0004 t4v 320 fixed (f), iu (40 c) = 320 a - icu (415 v) = 200 ka f = front terminals in 1sda.....r1 3 poles 4 poles electronic release t4v 320 f f pr221ds-ls/i 320 054149 054153 t4v 320 f f pr221ds-i 320 054150 054154 t4v 320 f f pr222ds/p-lsi 320 054151 054155 t4v 320 f f pr222ds/p-lsig 320 054152 054156 tmax and isomax power distribution circuit-breakers ordering details - t4 t4v 250 fixed (f), iu (40 c) = 250 a - icu (415 v) = 200 ka f = front terminals in 1sda.....r1 3 poles 4 poles electronic release t4v 250 f f pr221ds-ls/i 100 054093 054105 t4v 250 f f pr221ds-ls/i 160 054094 054106 t4v 250 f f pr221ds-ls/i 250 054095 054107 t4v 250 f f pr221ds-i 100 054096 054108 t4v 250 f f pr221ds-i 160 054097 054109 t4v 250 f f pr221ds-i 250 054098 054110 t4v 250 f f pr222ds/p-lsi 100 054099 054111 t4v 250 f f pr222ds/p-lsi 160 054100 054112 t4v 250 f f pr222ds/p-lsi 250 054101 054113 t4v 250 f f pr222ds/p-lsig 100 054102 054114 t4v 250 f f pr222ds/p-lsig 160 054103 054115 t4v 250 f f pr222ds/p-lsig 250 054104 054116 f = front terminals in i 3 1sda.....r1 3 poles 4 poles thermomagnetic release - tmd and tma n= 50% n= 100% t4v 250 f f 20 320 054243 054252 t4v 250 f f 32 320 054244 054253 t4v 250 f f 50 500 054245 054254 t4v 250 f f 80 400...800 054246 054255 t4v 250 f f 100 500...1000 054247 054256 t4v 250 f f 125 625...1250 054248 054257 054287 t4v 250 f f 160 800...1600 054249 054258 054288 t4v 250 f f 200 1000...2000 054250 054259 054289 t4v 250 f f 250 1250...2500 054251 054260 054290 0 7 0 2 _ t m a x 1 . i n d d 3 3 0702_tmax1.indd 33 4 - 0 3 - 2 0 0 5 1 2 : 1 7 : 5 4 4-03-2005 12:17:54 free datasheet http:///
1sdc007200c0201 7 /34 abb see ?abbreviation caption? page 7 /22 1sdc210189f0004 t4 trip units in 1sda.....r1 3 poles 4 poles electronic release pr221ds-ls/i 100 054603 054615 pr221ds-ls/i 160 054604 054616 pr221ds-ls/i 250 054605 054617 pr221ds-ls/i 320 054627 054631 pr221ds-i 100 054606 054618 pr221ds-i 160 054607 054619 pr221ds-i 250 054608 054620 pr221ds-i 320 054628 054632 pr222ds/p-lsi 100 054609 054621 pr222ds/p-lsi 160 054610 054622 pr222ds/p-lsi 250 054611 054623 pr222ds/p-lsi 320 054629 054633 pr222ds/p-lsig 100 054612 054624 pr222ds/p-lsig 160 054613 054625 pr222ds/p-lsig 250 054614 054626 pr222ds/p-lsig 320 054630 054634 pr222ds/pd-lsi 100 054635 054641 pr222ds/pd-lsi 160 054636 054642 pr222ds/pd-lsi 250 054637 054643 pr222ds/pd-lsi 320 054647 054649 pr222ds/pd-lsig 100 054638 054644 pr222ds/pd-lsig 160 054639 054645 pr222ds/pd-lsig 250 054640 054646 pr222ds/pd-lsig 320 054648 054650 in i 3 1sda.....r1 3 poles 4 poles thermomagnetic release - tmd and tma n= 50% n= 100% tmd 20-200 20 320 054651 054660 tmd 32-320 32 320 054652 054661 tmd 50-500 50 500 054653 054662 tma 80-800 80 800 054654 054663 tma 100-1000 100 1000 054655 054664 tma 125-1250 125 1250 054656 054665 054671 tma 160-1600 160 1600 054657 054666 054672 tma 200-2000 200 2000 054658 054667 054673 tma 250-2500 250 2500 054659 054668 054674 tmax and isomax power distribution circuit-breakers ordering details - t4 0 7 0 2 _ t m a x 1 . i n d d 3 4 0702_tmax1.indd 34 4 - 0 3 - 2 0 0 5 1 2 : 1 7 : 5 5 4-03-2005 12:17:55 free datasheet http:///
1sdc007200c0201 7 /35 abb mccbs see ?abbreviation caption? page 7 /22 1sdc210306f0004 t5n 400 fixed (f), iu (40 c) = 400 a - icu (415 v) = 36 ka f = front terminals in 1sda.....r1 3 poles 4 poles electronic release t5n 400 f f pr221ds-ls/i 320 054316 054324 t5n 400 f f pr221ds-ls/i 400 054317 054325 t5n 400 f f pr221ds-i 320 054318 054326 t5n 400 f f pr221ds-i 400 054319 054327 t5n 400 f f pr222ds/p-lsi 320 054320 054328 t5n 400 f f pr222ds/p-lsi 400 054321 054329 t5n 400 f f pr222ds/p-lsig 320 054322 054330 t5n 400 f f pr222ds/p-lsig 400 054323 054331 f = front terminals in i 3 1sda.....r1 3 poles 4 poles thermomagnetic release - tma n= 50% n= 100% t5n 400 f f 320 1600...3200 054436 054438 054477 t5n 400 f f 400 2000...4000 054437 054439 054478 t5n 630 fixed (f), iu (40 c) = 630 a - icu (415 v) = 36 ka f = front terminals in 1sda.....r1 3 poles 4 poles electronic release t5n 630 f f pr221ds-ls/i 630 054396 054400 t5n 630 f f pr221ds-i 630 054397 054401 t5n 630 f f pr222ds/p-lsi 630 054398 054402 t5n 630 f f pr222ds/p-lsig 630 054399 054403 f = front terminals in i 3 1sda.....r1 3 poles 4 poles thermomagnetic release - tma n= 50% n= 100% t5n 630 f f 500 2500...5000 054456 054459 054487 t5s 400 fixed (f), iu (40 c) = 400 a - icu (415 v) = 50 ka f = front terminals in 1sda.....r1 3 poles 4 poles electronic release t5s 400 f f pr221ds-ls/i 320 054332 054340 t5s 400 f f pr221ds-ls/i 400 054333 054341 t5s 400 f f pr221ds-i 320 054334 054342 t5s 400 f f pr221ds-i 400 054335 054343 t5s 400 f f pr222ds/p-lsi 320 054336 054344 t5s 400 f f pr222ds/p-lsi 400 054337 054345 t5s 400 f f pr222ds/p-lsig 320 054338 054346 t5s 400 f f pr222ds/p-lsig 400 054339 054347 f = front terminals in i 3 1sda.....r1 3 poles 4 poles thermomagnetic release - tma n= 50% n= 100% t5s 400 f f 320 1600...3200 054440 054442 054479 t5s 400 f f 400 2000...4000 054441 054443 054480 tmax and isomax power distribution circuit-breakers ordering details - t5 0 7 0 2 _ t m a x 1 . i n d d 3 5 0702_tmax1.indd 35 4 - 0 3 - 2 0 0 5 1 2 : 1 7 : 5 6 4-03-2005 12:17:56 free datasheet http:///
1sdc007200c0201 7 /36 abb see ?abbreviation caption? page 7 /22 t5s 630 fixed (f), iu (40 c) = 630 a - icu (415 v) = 50 ka f = front terminals in 1sda.....r1 3 poles 4 poles electronic release t5s 630 f f pr221ds-ls/i 630 054404 054408 t5s 630 f f pr221ds-i 630 054405 054409 t5s 630 f f pr222ds/p-lsi 630 054406 054410 t5s 630 f f pr222ds/p-lsig 630 054407 054411 f = front terminals in i 3 1sda.....r1 3 poles 4 poles thermomagnetic release - tma n= 50% n= 100% t5s 630 f f 500 2500...5000 054461 054463 054489 t5h 400 fixed (f), iu (40 c) = 400 a - icu (415 v) = 70 ka f = front terminals in 1sda.....r1 3 poles 4 poles electronic release t5h 400 f f pr221ds-ls/i 320 054348 054356 t5h 400 f f pr221ds-ls/i 400 054349 054357 t5h 400 f f pr221ds-i 320 054350 054358 t5h 400 f f pr221ds-i 400 054351 054359 t5h 400 f f pr222ds/p-lsi 320 054352 054360 t5h 400 f f pr222ds/p-lsi 400 054353 054361 t5h 400 f f pr222ds/p-lsig 320 054354 054362 t5h 400 f f pr222ds/p-lsig 400 054355 054363 f = front terminals in i 3 1sda.....r1 3 poles 4 poles thermomagnetic release - tma n= 50% n= 100% t5h 400 f f 320 1600...3200 054444 054446 054481 t5h 400 f f 400 2000...4000 054445 054447 054482 t5h 630 fixed (f), iu (40 c) = 630 a - icu (415 v) = 70 ka f = front terminals in 1sda.....r1 3 poles 4 poles electronic release t5h 630 f f pr221ds-ls/i 630 054412 054416 t5h 630 f f pr221ds-i 630 054413 054417 t5h 630 f f pr222ds/p-lsi 630 054414 054418 t5h 630 f f pr222ds/p-lsig 630 054415 054419 f = front terminals in i 3 1sda.....r1 3 poles 4 poles thermomagnetic release - tma n= 50% n= 100% t5h 630 f f 500 2500...5000 054465 054467 054491 tmax and isomax power distribution circuit-breakers ordering details - t5 1sdc210306f0004 0 7 0 2 _ t m a x 1 . i n d d 3 6 0702_tmax1.indd 36 4 - 0 3 - 2 0 0 5 1 2 : 1 7 : 5 7 4-03-2005 12:17:57 free datasheet http:///
1sdc007200c0201 7 /37 abb mccbs see ?abbreviation caption? page 7 /22 t5l 400 fixed (f), iu (40 c) = 400 a - icu (415 v) = 120 ka f = front terminals in 1sda.....r1 3 poles 4 poles electronic release t5l 400 f f pr221ds-ls/i 320 054364 054372 t5l 400 f f pr221ds-ls/i 400 054365 054373 t5l 400 f f pr221ds-i 320 054366 054374 t5l 400 f f pr221ds-i 400 054367 054375 t5l 400 f f pr222ds/p-lsi 320 054368 054376 t5l 400 f f pr222ds/p-lsi 400 054369 054377 t5l 400 f f pr222ds/p-lsig 320 054370 054378 t5l 400 f f pr222ds/p-lsig 400 054371 054379 f = front terminals in i 3 1sda.....r1 3 poles 4 poles thermomagnetic release - tma n= 50% n= 100% t5l 400 f f 320 1600...3200 054448 054450 054483 t5l 400 f f 400 2000...4000 054449 054451 054484 t5l 630 fixed (f), iu (40 c) = 630 a - icu (415 v) = 120 ka f = front terminals in 1sda.....r1 3 poles 4 poles electronic release t5l 630 f f pr221ds-ls/i 630 054420 054424 t5l 630 f f pr221ds-i 630 054421 054425 t5l 630 f f pr222ds/p-lsi 630 054422 054426 t5l 630 f f pr222ds/p-lsig 630 054423 054427 f = front terminals in i 3 1sda.....r1 3 poles 4 poles thermomagnetic release - tma n= 50% n= 100% t5l 630 f f 500 2500...5000 054469 054471 054493 t5v 400 fixed (f), iu (40 c) = 400 a - icu (415 v) = 200 ka f = front terminals in 1sda.....r1 3 poles 4 poles electronic release t5v 400 f f pr221ds-ls/i 320 054380 054388 t5v 400 f f pr221ds-ls/i 400 054381 054389 t5v 400 f f pr221ds-i 320 054382 054390 t5v 400 f f pr221ds-i 400 054383 054391 t5v 400 f f pr222ds/p-lsi 320 054384 054392 t5v 400 f f pr222ds/p-lsi 400 054385 054393 t5v 400 f f pr222ds/p-lsig 320 054386 054394 t5v 400 f f pr222ds/p-lsig 400 054387 054395 f = front terminals in i 3 1sda.....r1 3 poles 4 poles thermomagnetic release - tma n= 50% n= 100% t5v 400 f f 320 1600...3200 054452 054454 054485 t5v 400 f f 400 2000...4000 054453 054455 054486 tmax and isomax power distribution circuit-breakers ordering details - t5 1sdc210306f0004 0 7 0 2 _ t m a x 1 . i n d d 3 7 0702_tmax1.indd 37 4 - 0 3 - 2 0 0 5 1 2 : 1 7 : 5 8 4-03-2005 12:17:58 free datasheet http:///
1sdc007200c0201 7 /38 abb see ?abbreviation caption? page 7 /22 t5v 630 fixed (f), iu (40 c) = 630 a - icu (415 v) = 200 ka f = front terminals in 1sda.....r1 3 poles 4 poles electronic release t5v 630 f f pr221ds-ls/i 630 054428 054432 t5v 630 f f pr221ds-i 630 054429 054433 t5v 630 f f pr222ds/p-lsi 630 054430 054434 t5v 630 f f pr222ds/p-lsig 630 054431 054435 f = front terminals in i 3 1sda.....r1 3 poles 4 poles thermomagnetic release - tma n= 50% n= 100% t5v 630 f f 500 2500...5000 054473 054475 054495 t5 trip units in 1sda.....r1 3 poles 4 poles electronic release pr221ds-ls/i 320 054691 054699 pr221ds-ls/i 400 054692 054700 pr221ds-ls/i 630 054707 055159 pr221ds-i 320 054693 054701 pr221ds-i 400 054694 054702 pr221ds-i 630 054708 055160 pr222ds/p-lsi 320 054695 054703 pr222ds/p-lsi 400 054696 054704 pr222ds/p-lsi 630 054709 055161 pr222ds/p-lsig 320 054697 054705 pr222ds/p-lsig 400 054698 054706 pr222ds/p-lsig 630 054710 055162 pr222ds/pd-lsi 320 054711 054715 pr222ds/pd-lsi 400 054712 054716 pr222ds/pd-lsi 630 054719 054721 pr222ds/pd-lsig 320 054713 054717 pr222ds/pd-lsig 400 054714 054718 pr222ds/pd-lsig 630 054720 054722 in i 3 1sda.....r1 3 poles 4 poles thermomagnetic release - tma n= 50% n= 100% tma 320-1600 320 3200 054723 054725 054731 tma 400-2000 400 4000 054724 054726 054732 tma 500-2500 500 5000 054727 054729 054733 thermomagnetic release for generator protection - tmg n= 100% tmg 320-1600 320 1600 055093 055101 tmg 400-2000 400 2000 055098 055102 tmg 500-2500 500 2500 055099 055103 tmax and isomax power distribution circuit-breakers ordering details - t5 1sdc210189f0004 1sdc210306f0004 0 7 0 2 _ t m a x 1 . i n d d 3 8 0702_tmax1.indd 38 4 - 0 3 - 2 0 0 5 1 2 : 1 7 : 5 9 4-03-2005 12:17:59 free datasheet http:///
1sdc007200c0201 7 /39 abb mccbs see ?abbreviation caption? page 7 /22 tmax and isomax power distribution circuit-breakers ordering details - s6 psis9616 s6n 630 fixed (f), iu (40 c) = 630 a - icu (415 v) = 35 ka thermomagnetic release in i 3 1sda.....r1 3 poles 4 poles f = front terminals s6n 630 f f 630 6300 038787 038788 ef = extended front terminals s6n 630 f ef 630 6300 038789 038790 fc cual = front terminals for copper/aluminium cables s6n 630 f fc cual* 630 6300 038791 038792 r = threaded rear terminals s6n 630 f r 630 6300 038795 038796 rc = rear terminals for cables s6n 630 f rc 630 6300 038793 038794 electronic release in 1sda.....r1 3 poles 4 poles f = front terminals s6n 630 f f pr211/p-i 630 018518 018572 pr211/p-li 630 018519 018573 pr212/p-lsi 630 018520 018574 pr212/p-lsig 630 018523 018577 ef = extended front terminals s6n 630 f ef pr211/p-i 630 009806 009902 pr211/p-li 630 009807 009903 pr212/p-lsi 630 009808 009904 pr212/p-lsig 630 009811 009907 fc cual = front terminals for copper/aluminium cables s6n 630 f fc cual* pr211/p-i 630 009836 009932 pr211/p-li 630 009837 009933 pr212/p-lsi 630 009838 009934 pr212/p-lsig 630 009841 009937 r = threaded rear terminals s6n 630 f r pr211/p-i 630 009896 009992 pr211/p-li 630 009897 009993 pr212/p-lsi 630 009898 009994 pr212/p-lsig 630 009901 009997 rc = rear terminals for cables s6n 630 f rc pr211/p-i 630 009866 009962 pr211/p-li 630 009867 009963 pr212/p-lsi 630 009868 009964 pr212/p-lsig 630 009871 009967 * cable section = 1 x 240 mm 2 0 7 0 2 _ t m a x 1 . i n d d 3 9 0702_tmax1.indd 39 4 - 0 3 - 2 0 0 5 1 2 : 1 8 : 0 1 4-03-2005 12:18:01 free datasheet http:///
1sdc007200c0201 7 /40 abb s6s 630 fixed (f), iu (40 c) = 630 a - icu (415 v) = 50 ka thermomagnetic release in i 3 1sda.....r1 3 poles 4 poles f = front terminals s6s 630 f f 630 6300 038799 038800 ef = extended front terminals s6s 630 f ef 630 6300 038801 038802 fc cual = front terminals for copper/aluminium cables s6s 630 f fc cual* 630 6300 038817 038818 r = threaded rear terminals s6s 630 f r 630 6300 038957 038959 rc = rear terminals for cables s6s 630 f rc 630 6300 038819 038820 electronic release in 1sda.....r1 3 poles 4 poles f = front terminals s6s 630 f f pr211/p-i 630 018626 018680 pr211/p-li 630 018627 018681 pr212/p-lsi 630 018628 018682 pr212/p-lsig 630 018631 018685 ef = extended front terminals s6s 630 f ef pr211/p-i 630 010010 010106 pr211/p-li 630 010011 010107 pr212/p-lsi 630 010012 010108 pr212/p-lsig 630 010015 010111 fc cual = front terminals for copper/aluminium cables s6s 630 f fc cual* pr211/p-i 630 010040 010136 pr211/p-li 630 010041 010137 pr212/p-lsi 630 010042 010138 pr212/p-lsig 630 010045 010141 r = threaded rear terminals s6s 630 f r pr211/p-i 630 010100 010196 pr211/p-li 630 010101 010197 pr212/p-lsi 630 010102 010198 pr212/p-lsig 630 010105 010201 rc = rear terminals for cables s6s 630 f rc pr211/p-i 630 010070 010166 pr211/p-li 630 010071 010167 pr212/p-lsi 630 010072 010168 pr212/p-lsig 630 010075 010171 see ?abbreviation caption? page 7 /22 tmax and isomax power distribution circuit-breakers ordering details - s6 psis9616 * cable section = 1 x 240 mm 2 0 7 0 2 _ t m a x 1 . i n d d 4 0 0702_tmax1.indd 40 4 - 0 3 - 2 0 0 5 1 2 : 1 8 : 0 2 4-03-2005 12:18:02 free datasheet http:///
1sdc007200c0201 7 /41 abb mccbs see ?abbreviation caption? page 7 /22 tmax and isomax power distribution circuit-breakers ordering details - s6 psis9616 s6h 630 fixed (f), iu (40 c) = 630 a - icu (415 v) = 65 ka thermomagnetic release in i 3 1sda.....r1 3 poles 4 poles f = front terminals s6h 630 f f 630 6300 038823 038824 ef = extended front terminals s6h 630 f ef 630 6300 038825 038826 fc cual = front terminals for copper/aluminium cables s6h 630 f fc cual* 630 6300 038827 038835 r = threaded rear terminals s6h 630 f r 630 6300 038958 038960 rc = rear terminals for cables s6h 630 f rc 630 6300 038843 038844 electronic release in 1sda.....r1 3 poles 4 poles f = front terminals s6h 630 f f pr211/p-i 630 018734 018788 pr211/p-li 630 018735 018789 pr212/p-lsi 630 018736 018790 pr212/p-lsig 630 018739 018793 ef = extended front terminals s6h 630 f ef pr211/p-i 630 010214 010310 pr211/p-li 630 010215 010311 pr212/p-lsi 630 010216 010312 pr212/p-lsig 630 010219 010315 fc cual = front terminals for copper/aluminium cables s6h 630 f fc cual* pr211/p-i 630 010244 010340 pr211/p-li 630 010245 010341 pr212/p-lsi 630 010246 010342 pr212/p-lsig 630 010249 010345 r = threaded rear terminals s6h 630 f r pr211/p-i 630 010304 010400 pr211/p-li 630 010305 010401 pr212/p-lsi 630 010306 010402 pr212/p-lsig 630 010309 010405 rc = rear terminals for cables s6h 630 f rc pr211/p-i 630 010274 010370 pr211/p-li 630 010275 010371 pr212/p-lsi 630 010276 010372 pr212/p-lsig 630 010279 010375 * cable section = 1 x 240 mm 2 0 7 0 2 _ t m a x 1 . i n d d 4 1 0702_tmax1.indd 41 4 - 0 3 - 2 0 0 5 1 2 : 1 8 : 0 3 4-03-2005 12:18:03 free datasheet http:///
1sdc007200c0201 7 /42 abb see ?abbreviation caption? page 7 /22 tmax and isomax power distribution circuit-breakers ordering details - s6 psis9616 s6l 630 fixed (f), iu (40 c) = 630 a - icu (415 v) = 100 ka thermomagnetic release in i 3 1sda.....r1 3 poles 4 poles f = front terminals s6l 630 f f 630 6300 038847 038848 ef = extended front terminals s6l 630 f ef 630 6300 038849 038850 fc cual = front terminals for copper/aluminium cables s6l 630 f fc cual* 630 6300 038851 038859 r = threaded rear terminals s6l 630 f r 630 6300 038961 038962 rc = rear terminals for cables s6l 630 f rc 630 6300 038867 038868 electronic release in 1sda.....r1 3 poles 4 poles f = front terminals s6l 630 f f pr211/p-i 630 018842 018896 pr211/p-li 630 018843 018897 pr212/p-lsi 630 018844 018898 pr212/p-lsig 630 018847 018901 ef = extended front terminals s6l 630 f ef pr211/p-i 630 010418 010514 pr211/p-li 630 010419 010515 pr212/p-lsi 630 010420 010516 pr212/p-lsig 630 010423 010519 fc cual = front terminals for copper/aluminium cables s6l 630 f fc cual* pr211/p-i 630 010448 010544 pr211/p-li 630 010449 010545 pr212/p-lsi 630 010450 010546 pr212/p-lsig 630 010453 010549 r = threaded rear terminals s6l 630 f r pr211/p-i 630 010508 010604 pr211/p-li 630 010509 010605 pr212/p-lsi 630 010510 010606 pr212/p-lsig 630 010513 010609 rc = rear terminals for cables s6l 630 f rc pr211/p-i 630 010478 010574 pr211/p-li 630 010479 010575 pr212/p-lsi 630 010480 010576 pr212/p-lsig 630 010483 010579 * cable section = 1 x 240 mm 2 0 7 0 2 _ t m a x 1 . i n d d 4 2 0702_tmax1.indd 42 4 - 0 3 - 2 0 0 5 1 2 : 1 8 : 0 4 4-03-2005 12:18:04 free datasheet http:///
1sdc007200c0201 7 /43 abb mccbs see ?abbreviation caption? page 7 /22 tmax and isomax power distribution circuit-breakers ordering details - s6 psis9616 moving part s6n 630 withdrawable (w), iu (40 c) = 630 a - icu (415 v) = 35 ka thermomagnetic release in i 3 1sda.....r1 3 poles 4 poles s6n 630 w mp 630 6300 038785 038786 electronic release in 1sda.....r1 3 poles 4 poles s6n 630 w mp pr211/p-i 630 009998 010004 pr211/p-li 630 009999 010005 pr212/p-lsi 630 010000 010006 pr212/p-lsig 630 010003 010009 s6s 630 withdrawable (w), iu (40 c) = 630 a - icu (415 v) = 50 ka thermomagnetic release in i 3 1sda.....r1 3 poles 4 poles s6s 630 w mp 630 6300 038797 038798 electronic release in 1sda.....r1 3 poles 4 poles s6s 630 w mp pr211/p-i 630 010202 010208 pr211/p-li 630 010203 010209 pr212/p-lsi 630 010204 010210 pr212/p-lsig 630 010207 010213 s6h 630 withdrawable (w), iu (40 c) = 630 a - icu (415 v) = 65 ka thermomagnetic release in i 3 1sda.....r1 3 poles 4 poles s6h 630 w mp 630 6300 038821 038822 electronic release in 1sda.....r1 3 poles 4 poles s6h 630 w mp pr211/p-i 630 010406 010412 pr211/p-li 630 010407 010413 pr212/p-lsi 630 010408 010414 pr212/p-lsig 630 010411 010417 s6l 630 withdrawable (w), iu (40 c) = 630 a - icu (415 v) = 100 ka thermomagnetic release in i 3 1sda.....r1 3 poles 4 poles s6l 630 w mp 630 6300 038845 038846 electronic release in 1sda.....r1 3 poles 4 poles s6l 630 w mp pr211/p-i 630 010610 010616 pr211/p-li 630 010611 010617 pr212/p-lsi 630 010612 010618 pr212/p-lsig 630 010615 010621 a 0 7 0 2 _ t m a x 1 . i n d d 4 3 0702_tmax1.indd 43 4 - 0 3 - 2 0 0 5 1 2 : 1 8 : 0 5 4-03-2005 12:18:05 free datasheet http:///
1sdc007200c0201 7 /44 abb see ?abbreviation caption? page 7 /22 tmax and isomax power distribution circuit-breakers ordering details - s6 psis9616 s6n 800 fixed (f), iu (40 c) = 800 a - icu (415 v) = 35 ka thermomagnetic release in i 3 1sda.....r1 3 poles 4 poles f = front terminals s6n 800 f f 800 8000 038871 038872 ef = extended front terminals s6n 800 f ef 800 8000 038873 038874 fc cual = front terminals for copper/aluminium cables s6n 800 f fc cual* 800 8000 038875 038876 r = threaded rear terminals s6n 800 f r 800 8000 038879 038880 rc = rear terminals for cables s6n 630 f rc 800 8000 038877 038878 electronic release in 1sda.....r1 3 poles 4 poles f = front terminals s6n 800 f f pr211/p-i 800 018950 019004 pr211/p-li 800 018951 019005 pr212/p-lsi 800 018952 019006 pr212/p-lsig 800 018955 019009 ef = extended front terminals s6n 800 f ef pr211/p-i 800 010622 010718 pr211/p-li 800 010623 010719 pr212/p-lsi 800 010624 010720 pr212/p-lsig 800 010627 010723 fc cual = front terminals for copper/aluminium cables s6n 800 f fc cual* pr211/p-i 800 010652 010748 pr211/p-li 800 010653 010749 pr212/p-lsi 800 010654 010750 pr212/p-lsig 800 010657 010753 r = threaded rear terminals s6n 800 f r pr211/p-i 800 010712 010808 pr211/p-li 800 010713 010809 pr212/p-lsi 800 010714 010810 pr212/p-lsig 800 010717 010813 rc = rear terminals for cables s6n 800 f rc pr211/p-i 800 010682 010778 pr211/p-li 800 010683 010779 pr212/p-lsi 800 010684 010780 pr212/p-lsig 800 010687 010783 * cable section = 1 x 240 mm 2 0 7 0 2 _ t m a x 1 . i n d d 4 4 0702_tmax1.indd 44 4 - 0 3 - 2 0 0 5 1 2 : 1 8 : 0 6 4-03-2005 12:18:06 free datasheet http:///
1sdc007200c0201 7 /45 abb mccbs see ?abbreviation caption? page 7 /22 s6s 800 fixed (f), iu (40 c) = 800 a - icu (415 v) = 50 ka thermomagnetic release in i 3 1sda.....r1 3 poles 4 poles f = front terminals s6s 800 f f 800 8000 038883 038884 ef = extended front terminals s6s 800 f ef 800 8000 038885 038886 fc cual = front terminals for copper/aluminium cables s6s 800 f fc cual* 800 8000 038887 038895 r = threaded rear terminals s6s 800 f r 800 8000 038963 038964 rc = rear terminals for cables s6s 800 f rc 800 8000 038903 038904 electronic release in 1sda.....r1 3 poles 4 poles f = front terminals s6s 800 f f pr211/p-i 800 019058 019112 pr211/p-li 800 019059 019113 pr212/p-lsi 800 019060 019114 pr212/p-lsig 800 019063 019117 ef = extended front terminals s6s 800 f ef pr211/p-i 800 010826 010922 pr211/p-li 800 010827 010923 pr212/p-lsi 800 010828 010924 pr212/p-lsig 800 010831 010927 fc cual = front terminals for copper/aluminium cables s6s 800 f fc cual* pr211/p-i 800 010856 010952 pr211/p-li 800 010857 010953 pr212/p-lsi 800 010858 010954 pr212/p-lsig 800 010861 010957 r = threaded rear terminals s6s 800 f r pr211/p-i 800 010916 011006 pr211/p-li 800 010917 011007 pr212/p-lsi 800 010918 011008 pr212/p-lsig 800 010921 011011 rc = rear terminals for cables s6s 800 f rc pr211/p-i 800 010886 010976 pr211/p-li 800 010887 010977 pr212/p-lsi 800 010888 010978 pr212/p-lsig 800 010891 010981 tmax and isomax power distribution circuit-breakers ordering details - s6 psis9616 * cable section = 1 x 240 mm 2 0 7 0 2 _ t m a x 1 . i n d d 4 5 0702_tmax1.indd 45 4 - 0 3 - 2 0 0 5 1 2 : 1 8 : 0 6 4-03-2005 12:18:06 free datasheet http:///
1sdc007200c0201 7 /46 abb see ?abbreviation caption? page 7 /22 s6h 800 fixed (f), iu (40 c) = 800 a - icu (415 v) = 65 ka thermomagnetic release in i 3 1sda.....r1 3 poles 4 poles f = front terminals s6h 800 f f 800 8000 038907 038908 ef = extended front terminals s6h 800 f ef 800 8000 038909 038910 fc cual = front terminals for copper/aluminium cables s6h 800 f fc cual* 800 8000 038911 038919 r = threaded rear terminals s6h 800 f r 800 8000 038965 038966 rc = rear terminals for cables s6h 800 f rc 800 8000 038927 038928 electronic release in 1sda.....r1 3 poles 4 poles f = front terminals s6h 800 f f pr211/p-i 800 019166 019220 pr211/p-li 800 019167 019221 pr212/p-lsi 800 019168 019222 pr212/p-lsig 800 019171 019225 ef = extended front terminals s6h 800 f ef pr211/p-i 800 011024 011120 pr211/p-li 800 011025 011121 pr212/p-lsi 800 011026 011122 pr212/p-lsig 800 011029 011125 fc cual = front terminals for copper/aluminium cables s6h 800 f fc cual* pr211/p-i 800 011054 011150 pr211/p-li 800 011055 011151 pr212/p-lsi 800 011056 011152 pr212/p-lsig 800 011059 011155 r = threaded rear terminals s6h 800 f r pr211/p-i 800 011114 011210 pr211/p-li 800 011115 011211 pr212/p-lsi 800 011116 011212 pr212/p-lsig 800 011119 011215 rc = rear terminals for cables s6h 800 f rc pr211/p-i 800 011084 011180 pr211/p-li 800 011085 011181 pr212/p-lsi 800 011086 011182 pr212/p-lsig 800 011089 011185 tmax and isomax power distribution circuit-breakers ordering details - s6 psis9616 * cable section = 1 x 240 mm 2 0 7 0 2 _ t m a x 1 . i n d d 4 6 0702_tmax1.indd 46 4 - 0 3 - 2 0 0 5 1 2 : 1 8 : 0 7 4-03-2005 12:18:07 free datasheet http:///
1sdc007200c0201 7 /47 abb mccbs see ?abbreviation caption? page 7 /22 tmax and isomax power distribution circuit-breakers ordering details - s6 psis9616 s6l 800 fixed (f), iu (40 c) = 800 a - icu (415 v) = 100 ka thermomagnetic release in i 3 1sda.....r1 3 poles 4 poles f = front terminals s6l 800 f f 800 8000 038931 038932 ef = extended front terminals s6l 800 f ef 800 8000 038933 038934 fc cual = front terminals for copper/aluminium cables s6l 800 f fc cual* 800 8000 038935 038943 r = threaded rear terminals s6l 800 f r 800 8000 038973 038974 rc = rear terminals for cables s6l 800 f rc 800 8000 038951 038952 electronic release in 1sda.....r1 3 poles 4 poles f = front terminals s6l 800 f f pr211/p-i 800 019274 019328 pr211/p-li 800 019275 019329 pr212/p-lsi 800 019276 019330 pr212/p-lsig 800 019279 019333 ef = extended front terminals s6l 800 f ef pr211/p-i 800 011228 011324 pr211/p-li 800 011229 011325 pr212/p-lsi 800 011230 011326 pr212/p-lsig 800 011233 011329 fc cual = front terminals for copper/aluminium cables s6l 800 f fc cual* pr211/p-i 800 011258 011354 pr211/p-li 800 011259 011355 pr212/p-lsi 800 011260 011356 pr212/p-lsig 800 011263 011359 r = threaded rear terminals s6l 800 f r pr211/p-i 800 011318 011414 pr211/p-li 800 011319 011415 pr212/p-lsi 800 011320 011416 pr212/p-lsig 800 011323 011419 rc = rear terminals for cables s6l 800 f rc pr211/p-i 800 011288 011384 pr211/p-li 800 011289 011385 pr212/p-lsi 800 011290 011386 pr212/p-lsig 800 011293 011389 * cable section = 1 x 240 mm 2 0 7 0 2 _ t m a x 1 . i n d d 4 7 0702_tmax1.indd 47 4 - 0 3 - 2 0 0 5 1 2 : 1 8 : 0 8 4-03-2005 12:18:08 free datasheet http:///
1sdc007200c0201 7 /48 abb see ?abbreviation caption? page 7 /22 tmax and isomax power distribution circuit-breakers ordering details - s6 psis9616 moving part s6n 800 withdrawable (w), iu (40 c) = 800 a - icu (415 v) = 35 ka thermomagnetic release in i 3 1sda.....r1 3 poles 4 poles s6n 800 w mp 800 8000 038869 038870 electronic release in 1sda.....r1 3 poles 4 poles s6n 800 w mp pr211/p-i 800 010814 010820 pr211/p-li 800 010815 010821 pr212/p-lsi 800 010816 010822 pr212/p-lsig 800 010819 010825 s6s 800 withdrawable (w), iu (40 c) = 800 a - icu (415 v) = 50 ka thermomagnetic release in i 3 1sda.....r1 3 poles 4 poles s6s 800 w mp 800 8000 038881 038882 electronic release in 1sda.....r1 3 poles 4 poles s6s 800 w mp pr211/p-i 800 011012 011018 pr211/p-li 800 011013 011019 pr212/p-lsi 800 011014 011020 pr212/p-lsig 800 011017 011023 s6h 800 withdrawable (w), iu (40 c) = 800 a - icu (415 v) = 65 ka thermomagnetic release in i 3 1sda.....r1 3 poles 4 poles s6h 800 w mp 800 8000 038905 038906 electronic release in 1sda.....r1 3 poles 4 poles s6h 800 w mp pr211/p-i 800 011216 011222 pr211/p-li 800 011217 011223 pr212/p-lsi 800 011218 011224 pr212/p-lsig 800 011221 011227 s6l 800 withdrawable (w), iu (40 c) = 800 a - icu (415 v) = 100 ka thermomagnetic release in i 3 1sda.....r1 3 poles 4 poles s6l 800 w mp 800 8000 038929 038930 electronic release in 1sda.....r1 3 poles 4 poles s6l 800 w mp pr211/p-i 800 011420 011682 pr211/p-li 800 011421 011683 pr212/p-lsi 800 011422 011684 pr212/p-lsig 800 011425 011687 0 7 0 2 _ t m a x 1 . i n d d 4 8 0702_tmax1.indd 48 4 - 0 3 - 2 0 0 5 1 2 : 1 8 : 0 9 4-03-2005 12:18:09 free datasheet http:///
1sdc007200c0201 7 /49 abb mccbs see ?abbreviation caption? page 7 /22 s7s 1250 fixed (f), iu (40 c) = 1250 a - icu (415 v) = 50 ka electronic release in 1sda.....r1 3 poles 4 poles f = front terminals s7s 1250 f f pr211/p-i 1000 019382 019490 pr211/p-li 1000 019384 019492 pr212/p-lsi 1000 019386 019494 pr212/p-lsig 1000 019392 019500 s7s 1250 f f pr211/p-i 1250 019383 019491 pr211/p-li 1250 019385 019493 pr212/p-lsi 1250 019387 019495 pr212/p-lsig 1250 019393 019501 ef = extended front terminals s7s 1250 f ef pr211/p-i 1000 011432 011624 pr211/p-li 1000 011434 011626 pr212/p-lsi 1000 011436 011628 pr212/p-lsig 1000 011442 011634 s7s 1250 f ef pr211/p-i 1250 011433 011625 pr211/p-li 1250 011435 011627 pr212/p-lsi 1250 011437 011629 pr212/p-lsig 1250 011443 011635 fc cual = front terminals for copper/aluminium cables s7s 1250 f fc cual pr211/p-i 1000 011492 011428 pr211/p-li 1000 011494 011430 pr212/p-lsi 1000 011496 011688 pr212/p-lsig 1000 011502 011694 s7s 1250 f fc cual pr211/p-i 1250 011493 011429 pr211/p-li 1250 011495 011431 pr212/p-lsi 1250 011497 011689 pr212/p-lsig 1250 011503 011695 vr = vertical flat-bar rear terminals s7s 1250 f vr pr211/p-i 1000 011612 011804 pr211/p-li 1000 011614 011806 pr212/p-lsi 1000 011616 011808 pr212/p-lsig 1000 011622 011814 s7s 1250 f vr pr211/p-i 1250 011613 011805 pr211/p-li 1250 011615 011807 pr212/p-lsi 1250 011617 011809 pr212/p-lsig 1250 011623 011815 hr = horizontal flat-bar rear terminals s7s 1250 f hr pr211/p-i 1000 011552 011744 pr211/p-li 1000 011554 011746 pr212/p-lsi 1000 011556 011748 pr212/p-lsig 1000 011562 011754 s7s 1250 f hr pr211/p-i 1250 011553 011745 pr211/p-li 1250 011555 011747 pr212/p-lsi 1250 011557 011749 pr212/p-lsig 1250 011563 011755 tmax and isomax power distribution circuit-breakers ordering details - s7 psis9620 0 7 0 2 _ t m a x 1 . i n d d 4 9 0702_tmax1.indd 49 4 - 0 3 - 2 0 0 5 1 2 : 1 8 : 1 0 4-03-2005 12:18:10 free datasheet http:///
1sdc007200c0201 7 /50 abb see ?abbreviation caption? page 7 /22 tmax and isomax power distribution circuit-breakers ordering details - s7 psis9620 s7h 1250 fixed (f), iu (40 c) = 1250 a - icu (415 v) = 65 ka electronic release in 1sda.....r1 3 poles 4 poles f = front terminals s7h 1250 f f pr211/p-i 1000 019598 019706 pr211/p-li 1000 019600 019708 pr212/p-lsi 1000 019602 019710 pr212/p-lsig 1000 019608 019716 s7h 1250 f f pr211/p-i 1250 019599 019707 pr211/p-li 1250 019601 019709 pr212/p-lsi 1250 019603 019711 pr212/p-lsig 1250 019609 019717 ef = extended front terminals s7h 1250 f ef pr211/p-i 1000 011840 012032 pr211/p-li 1000 011842 012034 pr212/p-lsi 1000 011844 012036 pr212/p-lsig 1000 011850 012042 s7h 1250 f ef pr211/p-i 1250 011841 012033 pr211/p-li 1250 011843 012035 pr212/p-lsi 1250 011845 012037 pr212/p-lsig 1250 011851 012043 fc cual = front terminals for copper/aluminium cables s7h 1250 f fc cual pr211/p-i 1000 011900 012092 pr211/p-li 1000 011902 012094 pr212/p-lsi 1000 011904 012096 pr212/p-lsig 1000 011910 012102 s7h 1250 f fc cual pr211/p-i 1250 011901 012093 pr211/p-li 1250 011903 012095 pr212/p-lsi 1250 011905 012097 pr212/p-lsig 1250 011911 012103 vr = vertical flat-bar rear terminals s7h 1250 f vr pr211/p-i 1000 012020 012212 pr211/p-li 1000 012022 012214 pr212/p-lsi 1000 012024 012216 pr212/p-lsig 1000 012030 012222 s7h 1250 f vr pr211/p-i 1250 012021 012213 pr211/p-li 1250 012023 012215 pr212/p-lsi 1250 012025 012217 pr212/p-lsig 1250 012031 012223 hr = horizontal flat-bar rear terminals s7h 1250 f hr pr211/p-i 1000 011960 012152 pr211/p-li 1000 011962 012154 pr212/p-lsi 1000 011964 012156 pr212/p-lsig 1000 011970 012162 s7h 1250 f hr pr211/p-i 1250 011961 012153 pr211/p-li 1250 011963 012155 pr212/p-lsi 1250 011965 012157 pr212/p-lsig 1250 011971 012163 0 7 0 2 _ t m a x 1 . i n d d 5 0 0702_tmax1.indd 50 4 - 0 3 - 2 0 0 5 1 2 : 1 8 : 1 1 4-03-2005 12:18:11 free datasheet http:///
1sdc007200c0201 7 /51 abb mccbs see ?abbreviation caption? page 7 /22 tmax and isomax power distribution circuit-breakers ordering details - s7 psis9620 s7l 1250 fixed (f), iu (40 c) = 1250 a - icu (415 v) = 100 ka electronic release in 1sda.....r1 3 poles 4 poles f = front terminals s7l 1250 f f pr211/p-i 1000 019814 019922 pr211/p-li 1000 019816 019924 pr212/p-lsi 1000 019818 019926 pr212/p-lsig 1000 019824 019932 s7l 1250 f f pr211/p-i 1250 019815 019923 pr211/p-li 1250 019817 019925 pr212/p-lsi 1250 019819 019927 pr212/p-lsig 1250 019825 019933 ef = extended front terminals s7l 1250 f ef pr211/p-i 1000 012248 012440 pr211/p-li 1000 012250 012442 pr212/p-lsi 1000 012252 012444 pr212/p-lsig 1000 012258 012450 s7l 1250 f ef pr211/p-i 1250 012249 012441 pr211/p-li 1250 012251 012443 pr212/p-lsi 1250 012253 012445 pr212/p-lsig 1250 012259 012451 fc cual = front terminals for copper/aluminium cables s7l 1250 f fc cual pr211/p-i 1000 012308 012500 pr211/p-li 1000 012310 012502 pr212/p-lsi 1000 012312 012504 pr212/p-lsig 1000 012318 012510 s7l 1250 f fc cual pr211/p-i 1250 012309 012501 pr211/p-li 1250 012311 012503 pr212/p-lsi 1250 012313 012505 pr212/p-lsig 1250 012319 012511 vr = vertical flat-bar rear terminals s7l 1250 f vr pr211/p-i 1000 012428 012620 pr211/p-li 1000 012430 012622 pr212/p-lsi 1000 012432 012624 pr212/p-lsig 1000 012438 012630 s7l 1250 f vr pr211/p-i 1250 012429 012621 pr211/p-li 1250 012431 012623 pr212/p-lsi 1250 012433 012625 pr212/p-lsig 1250 012439 012631 hr = horizontal flat-bar rear terminals s7l 1250 f hr pr211/p-i 1000 012368 012560 pr211/p-li 1000 012370 012562 pr212/p-lsi 1000 012372 012564 pr212/p-lsig 1000 012378 012570 s7l 1250 f hr pr211/p-i 1250 012369 012561 pr211/p-li 1250 012371 012563 pr212/p-lsi 1250 012373 012565 pr212/p-lsig 1250 012379 012571 0 7 0 2 _ t m a x 1 . i n d d 5 1 0702_tmax1.indd 51 4 - 0 3 - 2 0 0 5 1 2 : 1 8 : 1 2 4-03-2005 12:18:12 free datasheet http:///
1sdc007200c0201 7 /52 abb see ?abbreviation caption? page 7 /22 tmax and isomax power distribution circuit-breakers ordering details - s7 psis9620 moving part s7s 1250 withdrawable (w), iu (40 c) = 1250 a - icu (415 v) = 50 ka electronic release in 1sda.....r1 3 poles 4 poles s7s 1250 w mp pr211/p-i 1000 011816 011828 pr211/p-li 1000 011818 011830 pr212/p-lsi 1000 011820 011832 pr212/p-lsig 1000 011826 011838 s7s 1250 w mp pr211/p-i 1250 011817 011829 pr211/p-li 1250 011819 011831 pr212/p-lsi 1250 011821 011833 pr212/p-lsig 1250 011827 011839 s7h 1250 withdrawable (w), iu (40 c) = 1250 a - icu (415 v) = 65 ka electronic release in 1sda.....r1 3 poles 4 poles s7h 1250 w mp pr211/p-i 1000 012224 012236 pr211/p-li 1000 012226 012238 pr212/p-lsi 1000 012228 012240 pr212/p-lsig 1000 012234 012246 s7h 1250 w mp pr211/p-i 1250 012225 012237 pr211/p-li 1250 012227 012239 pr212/p-lsi 1250 012229 012241 pr212/p-lsig 1250 012235 012247 s7l 1250 withdrawable (w), iu (40 c) = 1250 a - icu (415 v) = 100 ka electronic release in 1sda.....r1 3 poles 4 poles s7l 1250 w mp pr211/p-i 1000 012632 012644 pr211/p-li 1000 012634 012646 pr212/p-lsi 1000 012636 012648 pr212/p-lsig 1000 012642 012654 s7l 1250 w mp pr211/p-i 1250 012633 012645 pr211/p-li 1250 012635 012647 pr212/p-lsi 1250 012637 012649 pr212/p-lsig 1250 012643 012655 0 7 0 2 _ t m a x 1 . i n d d 5 2 0702_tmax1.indd 52 4 - 0 3 - 2 0 0 5 1 2 : 1 8 : 1 4 4-03-2005 12:18:14 free datasheet http:///
1sdc007200c0201 7 /53 abb mccbs see ?abbreviation caption? page 7 /22 tmax and isomax power distribution circuit-breakers ordering details - s7 psis9620 s7s 1600 fixed (f), iu (40 c) = 1600 a - icu (415 v) = 50 ka electronic release in 1sda.....r1 3 poles 4 poles f = front terminals s7s 1600 f f pr211/p-i 1600 020030 020072 pr211/p-li 1600 020031 020073 pr212/p-lsi 1600 020032 020074 pr212/p-lsig 1600 020035 020077 ef = extended front terminals s7s 1600 f ef pr211/p-i 1600 012656 012710 pr211/p-li 1600 012657 012711 pr212/p-lsi 1600 012658 012712 pr212/p-lsig 1600 012661 012715 vr = vertical flat-bar rear terminals s7s 1600 f vr pr211/p-i 1600 012704 012758 pr211/p-li 1600 012705 012759 pr212/p-lsi 1600 012706 012760 pr212/p-lsig 1600 012709 012763 hr = horizontal ? at-bar rear terminals s7s 1600 f hr pr211/p-i 1600 012680 012734 pr211/p-li 1600 012681 012735 pr212/p-lsi 1600 012682 012736 pr212/p-lsig 1600 012685 012739 s7h 1600 fixed (f), iu (40 c) = 1600 a - icu (415 v) = 65 ka electronic release in 1sda.....r1 3 poles 4 poles f = front terminals s7h 1600 f f pr211/p-i 1600 020114 020156 pr211/p-li 1600 020115 020157 pr212/p-lsi 1600 020116 020158 pr212/p-lsig 1600 020119 020161 ef = extended front terminals s7h 1600 f ef pr211/p-i 1600 012776 012830 pr211/p-li 1600 012777 012831 pr212/p-lsi 1600 012778 012832 pr212/p-lsig 1600 012781 012835 vr = vertical flat-bar rear terminals s7h 1600 f vr pr211/p-i 1600 012824 012878 pr211/p-li 1600 012825 012879 pr212/p-lsi 1600 012826 012880 pr212/p-lsig 1600 012829 012883 hr = horizontal ? at-bar rear terminals s7h 1600 f hr pr211/p-i 1600 012800 012854 pr211/p-li 1600 012801 012855 pr212/p-lsi 1600 012802 012856 pr212/p-lsig 1600 012805 012859 0 7 0 2 _ t m a x 1 . i n d d 5 3 0702_tmax1.indd 53 4 - 0 3 - 2 0 0 5 1 2 : 1 8 : 1 5 4-03-2005 12:18:15 free datasheet http:///
1sdc007200c0201 7 /54 abb see ?abbreviation caption? page 7 /22 tmax and isomax power distribution circuit-breakers ordering details - s7 psis9620 s7l 1600 fixed (f), iu (40 c) = 1600 a - icu (415 v) = 100 ka electronic release in 1sda.....r1 3 poles 4 poles f = front terminals s7l 1600 f f pr211/p-i 1600 020198 020240 pr211/p-li 1600 020199 020241 pr212/p-lsi 1600 020200 020242 pr212/p-lsig 1600 020203 020245 ef = extended front terminals s7l 1600 f ef pr211/p-i 1600 012896 012962 pr211/p-li 1600 012897 012963 pr212/p-lsi 1600 012898 012964 pr212/p-lsig 1600 012901 012967 vr = vertical flat-bar rear terminals s7l 1600 f vr pr211/p-i 1600 012956 013010 pr211/p-li 1600 012957 013011 pr212/p-lsi 1600 012958 013012 pr212/p-lsig 1600 012961 013015 hr = horizontal ? at-bar rear terminals s7l 1600 f hr pr211/p-i 1600 012932 012986 pr211/p-li 1600 012933 012987 pr212/p-lsi 1600 012934 012988 pr212/p-lsig 1600 012937 012991 0 7 0 2 _ t m a x 1 . i n d d 5 4 0702_tmax1.indd 54 4 - 0 3 - 2 0 0 5 1 2 : 1 8 : 1 6 4-03-2005 12:18:16 free datasheet http:///
1sdc007200c0201 7 /55 abb mccbs see ?abbreviation caption? page 7 /22 tmax and isomax power distribution circuit-breakers ordering details - s7 psis9620 moving part s7s 1600 withdrawable (w), iu (40 c) = 1600 a - icu (415 v) = 50 ka electronic release in 1sda.....r1 3 poles 4 poles s7s 1600 w mp pr211/p-i 1600 012764 012770 pr211/p-li 1600 012765 012771 pr212/p-lsi 1600 012766 012772 pr212/p-lsig 1600 012769 012775 s7h 1600 withdrawable (w), iu (40 c) = 1600 a - icu (415 v) = 65 ka electronic release in 1sda.....r1 3 poles 4 poles s7h 1600 w mp pr211/p-i 1600 012884 012890 pr211/p-li 1600 012885 012891 pr212/p-lsi 1600 012886 012892 pr212/p-lsig 1600 012889 012895 s7l 1600 withdrawable (w), iu (40 c) = 1600 a - icu (415 v) = 100 ka electronic release in 1sda.....r1 3 poles 4 poles s7l 1600 w mp pr211/p-i 1600 013016 013022 pr211/p-li 1600 013017 013023 pr212/p-lsi 1600 013018 013024 pr212/p-lsig 1600 013021 013027 0 7 0 2 _ t m a x 1 . i n d d 5 5 0702_tmax1.indd 55 4 - 0 3 - 2 0 0 5 1 2 : 1 8 : 1 6 4-03-2005 12:18:16 free datasheet http:///


▲Up To Search▲   

 
Price & Availability of T4N320

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X